Page 81 of 108
Adjustment instructions for the JUMBO application.
Tool For the adjustment you must use a trimming screwdriver, which can be purchased from LINAK A/S. It is also possible to use other types
of trimming screwdrivers for the adjustment.
Ordinary screwdrivers cannot be used, as they will damage the potentiometer slot.
When you receive the JUMBO from LINAK A/S it is adjusted to min. current cut-off.
1. Connect the JUMBO control box to the actuator.
2. Load the actuator with the required load.
3. Turn the potentiometer completely clockwise.
4. Run the actuator in the loaded direction at the same time turn the potentiometer anticlockwise until the actuator stops.
5. Turn the potentiometer 3 times clockwise.
6. Check JUMBO can lift the loaded actuator.
7. Insert the plugs article no. 0009020 (Light grey (RAL7035) or 0009019 (Dark grey (RAL7016) to ensure IP protection
Warning!
In order to avoid injury, the emergency-stop should be activated in (all) transport and cleaning situations.
Mounting of CBJ1 and CBJ2:
Recommendation:
• When charging, the CBJ1-2 will not be able to operate any actuators.
• By use of charger CH01 it is possible to activate the actuators when charging. However, this is not recommended as it can damage the control box
or the charger CH01.
Special care should be taken when mounting the CBJ.
As long as the the CBJ is mounted correctly then the CBJ complies to IPx5.
If the CBJ is mounted incorrectly then water will gather around the screw holes resulting in non-compliance with IPx5!
CBJ1/2 with variable current cut-off: the protection plugs must always be inserted to ensure IP protection after adjustment.
When using the control box with emergency stop, the stop button must be activated in cleaning situations in order to comply with IPx5.
The battery pack BAJ1/2 must not be removed in cleaning situations, doing so could result in non-compliance with IPx5.
The mains cable must always be ordered separately when ordering a CBJ with an internal charger.