DK Digital CDB-600 Specifiche Pagina 18

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 68
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 17
Chapter 6 The Extended Audio Matrix. PRELIMINARY Release MSD Software Manual.
6.3.1 Bargraph (PPM) Options.
To change the appearance of the individual 'Peak Programme Meter'
bargraphs move the green selection cursor to a destination number between
#65 and #96 column ‘OUTPUT and press [OPTION].
The bargraph option window has seven items. The X WIDE, WIDE and
NORMALsets the width of the selected bargraph. 'Wide' is the default setting.
The 'SPACEitem will if checked, insert an extra space at the right side of the
bargraph.
The colour of a bargraph can also be changed by using the colour selection
menu. A bargraph is divided into three fields, the top part - 'overload', the
bottom part - 'underload' and the middle part - 'normal'. The 'overload' part will
always be red, but the colour of the 'underload' and 'normal' parts can be
changed using ‘SET UNDERand ‘SET COLOUR items.
The colour selection menu.
SET TRACK’ will set the trace colour of the bargraph. When the trace colour is
set to another colour than black, the background of the bargraph will show the
highest bar reading until the the window is repainted or the [CLEAR] key in the
[METER] menu is pressed.
6.3.2 Audio Vector Scope Options.
To change the settings for the 'Audio Vector Oscilloscope' and the Jelly-Fish,
move the green selection cursor to a destination number between #53 and #62
in the column ‘OUTPUT and press [OPTION].
Please note that the only option available the Jelly-Fish (destination #55 to #62) is the
colour option. Please see section 6.3.2.3 for further information about this option.
6.3.2.1 Meter integration time.
The integration time for the 'Phase Correlation Meter' can by selecting either
[SLOW] or [FAST] be changed from 10mS. (slow) to no integration time
(fast).
6.3.2.2 Meter Compressor.
To obtain the best visual indication of signals in the 'Audio Vector Oscilloscope'
the 'Audio Vector Oscilloscope' uses dynamic scaling. This is done by adjusting
the input gain right before the metering function. The auto-adjustment are done
so that the average inputlevel results in a indication that fills most of the
window.
By selecting [C-OFF] the compressor is disabled and the input gain (and the
size of the image) can be set manually by using the gain [] / [] keys.
Note for PT0660M users: If the compressor is off, the input gain for the 'Audio
Vector Oscilloscope' can be adjusted using the wheeler. By pressing the [#2]
key, the compressor can be enabled or disabled. Pressing the [#1] key will
exit the options menu.
Page 14 of 64. PRELIMINARY Release
The upper part of the bargraph
options window.
Three PPM bars with different
widths and colours. The middle
PPM bar has the 'Track' colour
set to white.
Vedere la pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 67 68

Commenti su questo manuale

Nessun commento